Elecon Established in 1981,Elecon Group of Companies based at Meerut, Uttar Pradesh, in North India,Elecon Groups leading manufacturers of Power / Distribution / Instrument Transformers of various class & ratings. Besides this, Group is engaged in Production of Insulated/Bare Copper/Aluminum Strips & Wire and ACSR & AAAC Conductor, Instrument Transformers
 
Copper Division
Name ELECON
Address B-12, Industrial Estate, Partapur, Meerut-250103
Status Limited company
Manufacturing commenced in 1981
Capacity 1800 MT per annum
Total Area 20,000 sq ft.
Built-up Area 14,000 sq ft
Connected Load 200 KVA
 
Finished Goods Paper Insulated Strips Raw material Paper Coverning
 

Sl.No.

Products

Specification & Product Range

Application

1 VARNISH BONDED GLASS FIBER COVERED ROUND COPPER CONDUCTORS
Temperature 130°C, 155°C & 180°C

IS: 4685 PART I, 1968, 0.50 mm & above

Windings of electrical machines

2 VARNISH BONDED GLASS FIBRE COVERED RECTANGULAR COPPER CONDUCTORS
Temperature 120°C, 155°C & 180°C

IS: 4635 PART II, 1984, Width: 3.50 – 16.00 mm, Thickness: 1 – 5  mm, W/T ratio: Min 1.5:1 Max 1.5

Windings of AC/DC Motors

3 EPOXY VARNISH BONDED GLASS FIBRE COVERED RECTANGULAR COPPER CONDUCTORS
Temperature 155°C

Width: 3.50-16 mm, Thickness: 1 – 5  mm. W/T ratio: Min 1.5:1 Max 1.5

Windings of AC/DC Motors, Exciters, Hydro generators

4 SILICON VARNISH BONDED GLASS FIBRE COVERED RECTANGULAR COPPER CONDUCTOR
Temperature 180°C

Width: 3.5 – 16 mm Thickness: 1 – 5 mm W/T ratio: Min 1.5:1 Max 1.5

Windings of DC Motors, Traction, Traction Motors.

5 POLYESTER FILM & FIBRE GLASS LAPPED RECTANGULAR COPPER CONDUCTORS
Temperature 155°C

Width: 3.50 – 16.00 mm, Thickness: 1.00 – 5 mm, W/T ratio: Min 1.5:1 Max 1.5

Windings of Electrical A/C Machines

6 RECTANGULAR & SQUARE ENAMELED COPPER CONDUCTORS
Temperature 155°C & 180°C

IS – 3855 Part i to v, 1984, Width: 3.5 – 16 mm, Thickness:1 – 5 mm, ratio: Min 1.5:1 Max 1.5

Windings of electrical machines

7 ENAMELED & VARNISH BONDED GLASS FIBRE COVERED RECTANGULAR COPPER CONDUCTORS
Temperature 155°C & 180°C
IS – 10114, 1982, Width – 3.5 – 16 mm , Thickness: 1 – 5 mm, W/T ratio: Min 1.5:1 Max 1.5 Windings of Electrical A/C Motors
8 ENAMELED POLYESTER FILM & FIBRE GLASS LAPPED VARNISH BONDED RECTANGULAR COPPER CONDUCTORS
Temperature 180°C
Width – 3.5 – 16 mm , Thickness: 1 – 5 mm, W/T ratio: Min 1.5:1 Max 1.5 Windings of electrical a/c machines
9 VARNISH BONDED GLASS FIBRE BRAIDED RECTANGULAR COPPER CONDUCTORS
Temperature 155 °C & 180°C
IS – 6181, 1971, Width: 3.50 – 16.00 mm, Thickness: 1.00 – 5 mm, W/T ratio: Min 1.5:1 Max 1.5 Windings of Traction generator Armature & control coils
10 ENAMELED POLYESTER FILM & FIBRE GLASS LAPPED VARNISH BONDED RECTANGULAR COPPER CONDUCTORS
Temperature 180°C
Width: 3.50 – 16.00 mm, Thickness: 1.00 – 5.00 mm, W/T ratio: Min 1.5:1 Max 1.5 H.V. Motors, Hydro generators, Turbo generators.
11 ENAMELED ROUND COPPER CONDUCTORS
Temperature 155°C & 180°C
IS: 13730, 1973 2.00 mm and above Windings of Electrical Machines
12 ENAMELED & FIBRE GLASS LAPPED ROUND COPPER CONDUCTORS
Temperature 155°C & 180°C
IS: 11184, 1984 0.75 mm & Above Windings of Electrical Machines
13 KEPTON TAPE WRAPPED RECTANGULAR & SQUARE COPPER CONDUCTORS
Temperature 220°C
IS:9148, 1984, Width: 3.50 mm – 16.00 mm, Thickness: 1.00 – 5.00 mm, W/T ratio: Min 1.5:1 Max 1.5 Windings of Traction Motors
14 NOMEX COVERED RECTANGULAR COPPER CONDUCTORS
Temperature 220°C
IS: 11174, 1984, Width: 3.50 – 16.00 mm, Thickness: 1.00 – 5.00 mm, W/T ratio: Min 1.5:1 Max 1.5 UPS System
15 PAPER COVERED ROUND COPPER CONDUCTORS
Temperature 90°C
IS: 7404, Part I, 1974, 0.80 mm & above Windings of Transformers
16 PAPER COVERED RECTANGULAR COPPER CONDUCTORS
Temperature 90 - 105°C
 IS: 7404, Part II, 1974, Width: 3.50 – 16.00 mm, Thickness: 1.00 – 5.00 mm, W/T ratio: Min 1.5:1 Max 1.5 Windings of transformers
       
 
Grading Of Copper
Grade Type Of Copper
CATH Electrolytic cathode
ETP Electrolytic tough pitch
FRHC Fire-refined tough pitch
FRTP-1
FRTP-2
Fire-refined tough pitch
DHP Phosphorized, high residual phosphorus
ATP Arsenic, tough pitch
DPA Phosphorized, arsenical X-Commercially
   
 
 
 
 